Produktspecifikation
Produktspecifikation Strypelement Series MEF/2
Installationsguide
Installationsguide Strypelement Series MEF/2
The EMCO throttling element MEF/2 is used as a primary element in flow measurement of liquid, gas and vapour applications based on the differential pressure principle. According to this working principle, the throttling element creates a flow restriction in the pipeline to enable measurement of the resulting pressure drop and flow rate.
Strypelement MEF/2 is designed with a single pressure outlet for insertion between ring type joints (RTJ flanges).
Produktspecifikation Strypelement Series MEF/2
Installationsguide Strypelement Series MEF/2
| Design and calculation standards | ISO 5167-2 2003, ASME MFC-3M, ANSI B 16.5, Shell Flow Meter Engineering Handbook |
|---|---|
| Size | DN 50 - 600, 2" - 24" |
| Pressure class | 600 - 2500 lbs RTJ |
| Plate thickness | 3 - 8 mm |
| Material | AISI 316, AISI 304, 22Cr Duplex, 16Mo3, 13CrMo4-5, other materials on request. |
| Mounting style | Between flanges with RTJ according to ANSI B 16.5 or API |
| Accuracy | +/- 0.5 % for β < 0.6 and equal to β for β values above 0.6 |
| Limitations of Reynolds numbers | Re(D) > 5000 for 0.1 < β 0.56 according to ISO 5167-2 2003 |
| Pressure outlets | Threaded: ½" NPT int. (standard) or ½" BSP. Flanged: ½" and ¾", 600, 1500 and 2500 lbs RTJ. |
| Length of pressure outlets | 150 mm, other lengths on request |
| Location of pressure outlets | At least 45 degrees apart, to be specified when ordering |
| Withdrawal location | At least 15° apart, depending on size and pressure rating |
| Connectivity | Flanges with flat or raised face connection according to DIN 2526, 2513 or 2512, or RF according to ANSI B 16.5 |
| Shapes of the ironing box | Square edge concentric as standard. See above illustrations for other shapes |
| Labelling | The trace ring is labelled with "+" and "-" and the direction of flow. |
| Pressure drop | Depending on β, for β equal to 0.6: approx. 60 % of the measured differential pressure |
| Accessories | Shut-off valves and condensing chamber for vapour flow measurement. Flange assembly complete with bolts, nuts and gaskets |
| β (d/D) | 0,3 < β < 0,75 |
| Ventilation or drainage holes | On request |
| Tracking forms | Cutting edge concentric as standard. See above illustrations for other shapes. |
| Pressure loss | Depending on β, for β equal to 0.6: about 60 % of the measured differential pressure |
Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur. Excepteur sint occaecat cupidatat non proident, sunt in culpa qui officia deserunt mollit anim id est laborum.