Strypelement Series MES

Strypelement Series MES

Description of the programme

The EMCO tracer is used as a primary element in liquid, gas and vapour flow measurement, based on the differential pressure principle. According to this principle, the tracer creates a flow restriction in the pipeline to allow measurement of the resulting pressure drop and flow rate. Our tracer rings have been tried and tested for over 50 years and meet the highest industry and compliance standards.

The MES tracking ring series is designed with a single pressure outlet and fully welded construction.

Features and functions

  • Predictable pressure drop
  • Simple construction
  • Proven design
  • Cost-effective

Installation

Before installation, the groove ring must be kept clean and protected against corrosion and physical damage. It is also important to pay close attention to the sharp edge of the groove ring. Once it is ensured that the ring is clean, install it carefully so that the hole of the groove ring is centred with the centre of the pipeline. The location of the pressure tappings varies depending on whether the ring is used for liquid, gas or vapour. It is not supplied with any safety devices and must not be used at pressures higher than those indicated on the nameplate. The pipework must therefore be fitted with a safety device. However, this type of primary element requires no special maintenance.

Size

Produktspecifikation

Produktspecifikation Strypelement Series MES

Installationsguide

Installationsguide Strypelement Series MEF/2

Design and calculation standards

ISO 5167-2, ASME MFC-3M, DIN 19215, Shell Flow Meter Engineering Handbook, AGA No 3

Size

2" - 40", DN 50 - 1000

Plate thickness

10 mm

Material

Carbon steel P235GH, AISI 316, 16Mo3, 13CrMo4-5, 10CrMo9-10, WB 36, X20CrMoV121, other materials on request

Mounting style

Welding ends according to DIN 2559 or ANSI B16.25

Accuracy

+/- 0.5 % for β < 0.6 and equal to β for β values above 0.6

Limitations of Reynolds numbers

Re > 1260 x β² D according to ISO 5167
2000 < Re < 10⁸ according to ASME MFC-3M

Pressure outlets

Ø 21.3 mm, 24 mm, 26.9 mm, ½" BSP male, ½" NPT male

Length of pressure outlets

150 mm, other lengths on request

Location of pressure outlets

At least 45 degrees apart, to be specified when ordering

Withdrawal location

For vapour flow: 180°. Minimum 45° separation for liquid and gas. To be specified when ordering

Connectivity

Flanges with flat or raised face connection according to DIN 2526, 2513 or 2512, or RF according to ANSI B 16.5

Shapes of the ironing box

Square edge concentric as standard. See above illustrations for other shapes

Labelling

The trace ring is labelled with "+" and "-" and the direction of flow.

Pressure drop

Depending on β, for β equal to 0.6: approx. 60 % of the measured differential pressure

Accessories

Single and double shut-off valves and condensing chamber for vapour flow measurement

β (d/D)

0,3 < β < 0,75

Ventilation or drainage holes

On request

Tracking forms

Cutting edge concentric, cutting edge eccentric, conical, 1/4 circle, segment. The plate is bevelled on the downstream side except for the 1/4 circle groove

Pressure loss

Depending on β, for β equal to 0.6: about 60 % of the measured differential pressure

Withdrawal length

150 mm, other lengths on request

Brand

EMCO Controls

EMCO Controls specialises in flow and level measurement solutions. Their high-quality instruments are used to ensure accurate monitoring and control in various process industries.

Request a quote

Ask a question or request a quote!

Thank you very much, we will be in touch as soon as we can!