Number of simultaneous chemistries: |
1 – 6
|
Approved standards: |
ISO, EPA, ASTM, UKAS, CORESTA etc
|
Matrices: |
Drinking water, waste water, receiving water, industrial water, leachate, soil and plant samples, pharmaceuticals, food, drink (wine, beer, soft drinks), tobacco, animal feed, fertiliser, milk, detergents, etc.
|
Example methods: |
Nitrogen and phosphorus analyses, phenol index, cyanide (free and total), sugar, nicotine, etc.
|
Test speed: |
Depending on the chemistry
|
Blanking of samples: |
YES
|
Adding samples during the run: |
YES
|
Reagent level detector: |
YES
|
Reagent valves: |
YES
|
Automatic Start-up & Shut-down: |
YES
|
Automatic dilutions: |
YES
|
Automatic standard prep: |
YES
|
Segregated waste management: |
YES
|
Test tube size: |
2 mL, 5 mL, 10 mL, 11 mL, 15mL, 20 mL, 50 mL or customer specific
|
Sample rack number of pos..: |
21, 24, 40, 60, 90 or customised
|
Test needles: |
1 - 4 depending on system configuration
|
Dual sample changers: |
YES
|
Number of racks: |
2 (AS2), 4 (AS4), 6 (AS6), 8 (AS8), 10 (AS10)
|
Dimensions of sample exchangers: |
440mm x 470mm (AS2) up to 1400mm x 470 mm (AS10)
|
Weight of sample exchanger: |
15 - 31 kg
|
Separate standard rack |
YES - 12, 22, 42 pos. or customer specific
|
Ultrasonic mixing: |
YES - option
|
Stirring: |
YES - option
|
Sized syringes: |
5 mL, 10mL, 12 mL
|
Type of dilutions: |
Standards, pre-dilutions, post-dilutions
|
Type of pump: |
Peristaltic
|
Pump hose positions: |
34
|
Air vents: |
Electronic software-controlled valves
|
Pump discs "release & engage": |
YES
|
Multi-speed motor: |
YES
|
Leak detector: |
Pump, chemistry module, detectors
|
Thermal baths/Dest.unit: |
Solid-state (no oil required) - easy maintenance
|
In-line distillation: |
YES - depending on the method chosen
|
UV digesters: |
YES - depending on the method chosen
|
Dialysis unit: |
YES - depending on the method chosen
|
Aut. Cadmium valve: |
YES - option
|
poppet valves: |
YES - option
|
Kyvett size: |
10 mm - 50 mm (LWCC 100 cm also available)
|
Bubble-through cuvette: |
YES
|
Detector: |
Silicone photo-diode, Fluorometer, Flame photometer, Electro-chemical
|
Interference filters: |
270 - 880nm or customised filters
|
Lamp: |
LED - wavelength specific
|
Temperature stabilised: |
YES
|
Data Output: |
LIMS compatible, Export in SYLK(excel/csv), ASCII (Text format)
|
Computer requirements specification: |
Windows 7, 10 or 11
|
Barcode scanner: |
YES - external
|
Dimensions (mm): |
955 W x 350 D x 300 H (may be deeper depending on configuration)
|
Weight: |
23 - 45 kg
|
Power req: |
220 - 240V 50 HZ
|