Strypelement Series MEF/2

Strypelement Series MEF/2

Description of the programme

The EMCO tracer is used as a primary element in flow measurement of liquid, gas and vapour applications based on the differential pressure principle. According to this working principle, the tracer creates a flow restriction in the pipeline to allow measurement of the resulting pressure drop and flow rate.

The MEF/2 series is designed with a single push-in socket for insertion between ring type joints (RTJ flanges).

Features and functions

  • Predictable pressure drop
  • Simple construction
  • Proven design
  • Cost-effective

Produktspecifikation

Produktspecifikation Strypelement Series MEF/2

Installationsguide

Installationsguide Strypelement Series MEF/2

Design and calculation standards

ISO 5167-2 2003, ASME MFC-3M, ANSI B 16.5, Shell Flow Meter Engineering Handbook

Size

DN 50 - 600, 2" - 24"

Pressure class

600 - 2500 lbs RTJ

Plate thickness

3 - 8 mm

Material

AISI 316, AISI 304, 22Cr Duplex, 16Mo3, 13CrMo4-5, other materials on request.

Mounting style

Between flanges with RTJ according to ANSI B 16.5 or API

Accuracy

+/- 0.5 % for β < 0.6 and equal to β for β values above 0.6

Limitations of Reynolds numbers

Re(D) > 5000 for 0.1 < β 0.56 according to ISO 5167-2 2003
2000 < Re < 10⁸ according to ASME MFC-3M

Pressure outlets

Threaded: ½" NPT int. (standard) or ½" BSP. Flanged: ½" and ¾", 600, 1500 and 2500 lbs RTJ.

Length of pressure outlets

150 mm, other lengths on request

Location of pressure outlets

At least 45 degrees apart, to be specified when ordering

Withdrawal location

At least 15° apart, depending on size and pressure rating

Connectivity

Flanges with flat or raised face connection according to DIN 2526, 2513 or 2512, or RF according to ANSI B 16.5

Shapes of the ironing box

Square edge concentric as standard. See above illustrations for other shapes

Labelling

The trace ring is labelled with "+" and "-" and the direction of flow.

Pressure drop

Depending on β, for β equal to 0.6: approx. 60 % of the measured differential pressure

Accessories

Shut-off valves and condensing chamber for vapour flow measurement. Flange assembly complete with bolts, nuts and gaskets

β (d/D)

0,3 < β < 0,75

Ventilation or drainage holes

On request

Tracking forms

Cutting edge concentric as standard. See above illustrations for other shapes.

Pressure loss

Depending on β, for β equal to 0.6: about 60 % of the measured differential pressure

Brand

EMCO Controls

EMCO Controls specialises in flow and level measurement solutions. Their high-quality instruments are used to ensure accurate monitoring and control in various process industries.

Request a quote

Ask a question or request a quote!

Thank you very much, we will be in touch as soon as we can!